Hypoxic Training Index

The Hypoxic Training index (HTi) provides an objective measure of the hypoxic stress delivered during the Intermittent Hypoxic Training (IHT) session, compared to simple recording the inhaled fraction of oxygen (FiO2). HTi provides a figure (index) of dosage received by the individual at the end of the session.[1] Knowledge of HTi can therefore be used to alter the training regime for different individuals, compensating for individual variability, and can be used in scientific studies to ensure that subject exposure was correctly controlled.

Tissue hypoxia develops only when arterial oxygen saturation (SpO2) drops to 90% or below. This is due to the oxyhaemoglobin dissociation curve. Saturations above 90% produce very little effect or decrease of arterial oxygen partial pressure (PaO2). In order to obtain consistent and comparable values of HTi for different individuals the following conditions should be stipulated:

  • The values of SpO2 above 89% are not considered in the calculation of HTi, as such saturation levels do not contribute to the treatment. SpO2 values below 75% count as 75%.
  • HTi is calculated as an integral value of SpO2 readings made with 1 s sampling frequency and divided by 60 in order to produce a “per minute” value.
  • During the treatment target SpO2 values are in the range of 75% - 89%.
  1. ^ Bassovitch, O; Serebrovskaya, TV (2009). "Equipment and Regimes for Intermittent Hypoxia Therapy". In Lei Xi; Tatiana V. Serebrovskaya (eds.). Intermittent Hypoxia: From Molecular Mechanisms To Clinical Applications. Nova Science Publishers. pp. 589–601. ISBN 978-1-60876-127-2.