Specifications |
---|
AN/PVS-4 | |
---|---|
Type | Passive |
Place of origin | United States of America |
Category | Weaponscope |
Service history | |
In service | 1978–present |
Used by | United States of America |
Wars | Gulf War |
Production history | |
Designer | Optic Electronic Corporation of Dallas |
Designed | 1976 |
Manufacturer | Optic Electronic Corporation of Dallas |
Produced | 1977 |
No. built | 88047 in US alone |
Variants |
|
Specifications | |
Weight | 4 lb (1,800 g) |
Dimensions (L×H×W) | 320 mm (l) × 120 mm (h) × 100 mm (w) |
Resolution (lp/mm) | 32 |
Mode of Operation | Passive |
II tube | MX9644 |
Tube form factor | 25 mm |
Field of vision (°) | 14.5° |
Range of detection | 600 m (Starlight) |
Range of recognition | 400 m (Starlight) |
System zoom | 3.6× |
Generation | 2 |
Can use these tubes |
{{Infobox night vision device}} may be used to summarize information about a particular night vision device. This covers all practical NVDs and is based roughly on the Military History Infobox to maintain uniformity during information crossovers.
{{Infobox night vision device
| name =
| image =
| caption =
| origin =
| type =
| category =
<!-- Type selection -->
| is_thermal =
| is_tube =
| is_digital =
| is_iit =
<!-- Service history -->
| service =
| used_by =
| wars =
<!-- Production history -->
| designer =
| design_date =
| manufacturer =
| unit_cost =
| production_date =
| number =
| variants =
<!-- General specifications -->
| spec_label =
| weight =
| dimensions =
| adapter =
| batt_config =
| bridge_type =
| resolution =
| op_time =
| mode =
| wavelength =
<!-- Thermal NVD Specifications -->
| sensor =
| detector_res =
| refresh =
| fov =
| detection =
| recognition =
| zoom =
<!-- Tube Based Specifications -->
| iitube =
| form_factor =
| fov =
| detection =
| recognition =
| zoom =
| generation =
| subgen =
| illumination =
| system_gain =
| other_tubes =
<!-- Digital NVD Specifications -->
| detector_res =
| refresh =
| fov =
| detection =
| recognition =
| zoom =
| illumination =
<!-- IIT Specifications -->
| form_factor =
| zoom =
| generation =
| subgen =
| resolution_typ =
| resolution_min =
| gain =
| ebi =
| sn =
| sens =
| mttf =
| diopter =
}}
Note: When using parameters, avoid the ambiguous abbreviation "N/A", and instead use "unknown" or "none", or simply leave blank. All subjective or qualitative judgements and numerical quantities or statistics must be cited to a reliable source.
The infobox is intended as a quick reference. Don't add non-data items, like question marks, “none”, “see text” or links to article sections (the article's table of contents already does this). Only add “unknown” to assert that an information point is unknowable, not as a placeholder to show that it is missing from the article. Choose a representative model and indicate what it is with the spec_label
parameter, instead of listing multiple data items in one field.
Where multiple values are shown, separate them using {{Plainlist}} or {{Flatlist}}.
The template can also be used for general categories of NVD by including only some general characteristics.
General parameters:
Type selection parameters (these parameters control whether—and how—particular specification fields will be displayed; multiple ones may be enabled where appropriate):
Service history parameters:
Production history parameters:
General specification parameters:
Thermal NVD specification parameters (Available if is_thermal us set to "yes"):
Tube-based NVD specification parameters (Available if is_tube us set to "yes"):
Digital based NVD specification parameters (Available if is_tube us set to "yes"):
IIT device specification parameters, for describing specifications of an image intensifier tube, not a night vision device (Available if is_tube us set to "yes"):
If the product has a URL, use {{URL}} to include it.
The HTML classes of this microformat include: